Plant: RIICO Industrial Area, Khuskhera, Bhiwadi – 301707
R.K. Enterprises Logo
R.K. ENTERPRISES

Products

Tested to BS: 476 Part 22 / IS-3614 Part 2 / EN 1125 Panic Egress
PANIC EGRESS 120 MIN CSIR-CBRI TESTED
Fire Rated Exit Doors with Panic Hardware
1029°C Furnace Integrity
NBC 2016 Clause 4 Compliance
DELHI PLANT Direct Manufacturer
FIRE DOORS • SPECIFICATION-GRADE

Fire Rated Exit Doors with Panic Hardware

Emergency Egress Fire Doors Equipped with High-Capacity Push Touch Bars

High-traffic emergency fire escape doors equipped with UL-listed panic touch bars and automated door sequence control for rapid evacuation during building fires.

Engineering Parameter Readout IS:3614 / BS:476
Fire Resistance: 120 Minutes (2 Hours)
Shutter Thickness: 46 mm ± 2 mm
Testing Standard: BS: 476 Part 22 / IS-3614 Part 2 / EN 1125 Panic Egress
Accreditation: Tested & Certified at CSIR-CBRI Roorkee
Infill Core: Bonded mineral wool insulation core (96 kg/m³) with intumescent perimeter seals.
WhatsApp Quote
Direct Factory Desk: +91 9953476468 Instant Engineer Handoff
DETAILED ARCHITECTURAL SCHEDULE

Construction & Material Specifications

Fully compliant with IS:3614 Part 2 & BS:476 Part 22. Fabricated with mechanical lock seams and internal reinforcements.

Frame & Shutter Engineering IS:3614

Frame Profile:

Double rebate profile 143 x 57 mm in 16 gauge GI sheet with universal strike plates for panic hardware.

Shutter Skin & Seam:

46 mm thick double-skin galvanized steel with heavy internal steel backup plates for panic touchbar and top closer.

Thermal Infill Core:

Bonded mineral wool insulation core (96 kg/m³) with intumescent perimeter seals.

Vision Panel & Glazing:

Narrow optical fire glass vision lite (100 x 600 mm or 200 x 300 mm) conforming to BS: 476 Part 20.

Hardware Reinforcements:

UL-listed / CE-marked horizontal panic exit push-bar, outside trim lever, hydraulic door closer, and bottom drop seal.

Key Features & Furnace Test Criteria CSIR-CBRI

  • ✓Full EN 1125 & UL panic escape certification
  • ✓Heavy-duty internal reinforcements for crossbar mounting
  • ✓120 minutes furnace stability and integrity certified
  • ✓Factory pre-mortised and drilled for fast on-site installation

Recommended Project Applications & Egress Locations

Cinema multiplex fire exit routes
Shopping mall stairwell exits
Office tower fire egress corridors
School and university emergency exits
ESTABLISHED 2009 • HASTSAL INDUSTRIAL AREA, NEW DELHI

Need Custom Dimensions or Architect Shop Drawings?

Our New Delhi drafting desk prepares shop drawings, frame anchoring details, and BOQ schedules within 24 hours.

+91 9953476468
Direct Factory Engineering Desk +91 9953476468 Mon - Sat • 9:00 AM - 7:30 PM (IST)